Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
The Journal of the Korean Orthopaedic Association ; : 1334-1340, 1997.
Article in Korean | WPRIM | ID: wpr-645890

ABSTRACT

Soft-tissue defects over the plantar forefoot, plantar heel, Achilles tendon and distal parts of lower leg are often troublesome to cover with a simple graft or local flap due to limited mobility of surrounding skin and poor circulation in these area. Soft-tissue reconstruction in these regions should provide tissue components similar to the original lost tissue, supply durability and minimal protective pressure sensation and result in a donor site that is well tolerated. We analysed 14 cases that were treated with the instep flap due to soft-tissue defects over these regions from JuL 1990 to Oct. 1995. All flaps were viable and successful at follow-up. 1. The age ranged from 5 years to 70 years, and 13 cases were male and 1 case was female. 2. The sites of soft-tissue loss were the plantar forefoot (l case), plantar heel (9 cases), Achilles tendon (3 cases), and distal part of lower leg (1 case). 3. The causes of soft-tissue loss were simple soft-tissue injury (l case), crushing injury of the 1st toe (1 case), post-traumatic infection and necrosis (11 cases) and traction sore (1 case). 4. The associated injury were open distal tibio-fibular fractures (2 cases), medial malleolar fracture of the ankle (1 case), Achilles tendon ruptures (4 cases) and 1st metatarsophalangeal disarticulation (1 case), open calcaneus fracture (1 case) and femur shaft fracture (1 case). 5. The size of flap was from 3 1 cm to 5 10 cm (average 4 5 cm). 6. We could not find post-operative necrosis and infection, non-viability and gait disturbance caused by the instep flap surgery except limitation of the ankle joint in 1 case. In conclusion, this study demonstrates that the instep flap should be considered as another valuable technique in the reconstruction of these regions.


Subject(s)
Female , Humans , Male , Achilles Tendon , Ankle , Ankle Joint , Calcaneus , Disarticulation , Femur , Follow-Up Studies , Gait , Heel , Leg , Necrosis , Rupture , Sensation , Skin , Tissue Donors , Toes , Traction , Transplants
2.
The Journal of the Korean Orthopaedic Association ; : 580-589, 1995.
Article in Korean | WPRIM | ID: wpr-769681

ABSTRACT

The proper distribution of stress & a low rate of wear has become major concern in recent design consideration of total knee prosthesis. The TC IV knee system has kept the original anatomical design of the total condylar knee and improved and refined it. And it has some characteristics: deep patellar groove of the femoral component, 5 degree posterior tilted tibial UHMWPE articulating surface with increased potential range of motion, and beaded porous coating applied to the bone-component interface. This study reports the consecutive 61 arthroplasties in 42 patients. Follow up period was average three years and six months. There were 29 osteoarthritis, 29 rheumatoid arthritis, and three infection sequelae. In all cases, we used TC IV prosthesis, bone-cement for prosthesis fixation and sacrificed PCL. All patients were assessed using HSS knee score and American knee society clinical rating system, and roentgenographic evaluation and scoring system. 1. The range of motion was significantly increased from average 87.8 degrees preoperatively to average 122.9 degrees postoperatively. 2. The HSS knee score increased from average 47.7 points preoperatively to average 90.9 points postoperatively, and the functional score of AKS was average 85.6 and knee score was 93.4 postoperatively. 3. The flexion contracture was decreased from average 29.3 degrees preoperatively to average 3.9 degrees postoperatively. 4. In radiological review, the tibiofemoral angle changed from average varus 1.5 degrees preoperatively to average valgus 6.3 degrees postoperatively, and the joint line changed average 9.3mm preoperatively to average 13.7mm postoperatively, and nine knees(14%) had a radiolucency with a width of 2mm or more beneath one or two tibial zone. 5. Complications included two superficial infections and each case of transient peroneal palsy and patellar component wear in the metal backing type. 6. In summary, although the follow-up period was short, functional score of TC IV is no less than that of the other prosthesis with PCL retention.


Subject(s)
Humans , Arthritis, Rheumatoid , Arthroplasty , Arthroplasty, Replacement, Knee , Contracture , Follow-Up Studies , Joints , Knee , Knee Prosthesis , Osteoarthritis , Paralysis , Prostheses and Implants , Prosthesis Retention , Range of Motion, Articular
3.
The Journal of the Korean Orthopaedic Association ; : 1137-1141, 1992.
Article in Korean | WPRIM | ID: wpr-654722

ABSTRACT

No abstract available.


Subject(s)
Amputation, Surgical
SELECTION OF CITATIONS
SEARCH DETAIL